From furniture name
to buildable information.

A BOQ line describes what to buy. A technical specification explains what must be made, approved and inspected. Put the fields into the specification builder, then check them against the shop drawing audit.

01

Guestroom casegoods

Nightstand · desk · console · minibar · wardrobe · luggage bench

  1. Overall and interface dimensions
  2. Substrate and structural thickness
  3. Visible and concealed finish
  4. Hardware and access panels
  5. Electrical and ventilation interfaces
  6. Plinth, levelling and wall fixing
02

Upholstered sofa

Lobby · suite · lounge · restaurant

  1. Frame and joint construction
  2. Suspension system
  3. Foam layers and firmness
  4. Fabric or leather specification
  5. Seam, piping and cushion details
  6. Legs, glides and floor interface
03

Dining / lounge chair

Restaurant · lobby · guestroom

  1. Seat height and ergonomic dimensions
  2. Frame material and finish
  3. Seat and back construction
  4. Upholstery and seam details
  5. Glides and floor protection
  6. Stacking or non-stacking condition
04

Table & stone-top furniture

Dining · coffee · bedside · console

  1. Top material and actual slab approval
  2. Thickness, edge and underside support
  3. Base material and connection
  4. Levelling and anti-tip requirement
  5. Knock-down or assembled packing
  6. Weight and handling instructions
05

Bed & headboard system

Hotel guestroom · suite

  1. Mattress and bed-base interface
  2. Headboard module dimensions
  3. Upholstery and fire requirement
  4. Wall cleat or floor-standing fixing
  5. Power, lighting and switch coordination
  6. Removable panels and maintenance access

Project-specific, not catalogue-fixed.

Dimensions, material grades, fire performance, formaldehyde limits, test methods and hardware standards must be stated by the designer, operator, destination code or approved project specification. YUESHAN will not claim compliance without the corresponding material document, test report or approved sample.

Fire performance: which standard applies, and who issues the paper

Fire performance is set by the destination and the operator, not by the factory. A guestroom in the United States is usually specified against California Technical Bulletin 117 at component level, or CAL 133 where a full seating assembly must be tested for a public occupancy. A UK or Middle East project commonly cites BS 5852 for upholstered components and BS 7176 for contract seating by hazard category. European projects cite EN 1021 parts 1 and 2 for ignitability, or EN 13501 for reaction to fire at building level. The specification should name the standard, the test and the component it applies to, because a fabric certificate does not prove that the finished sofa passes an assembly test.

The standards most often cited, and what each one actually covers
StandardWhat it normally coversWhat the buyer must confirm
US: CAL TB 117 (2013)Flexible foam and filling materials at component levelThat the tested component is the one being supplied
US: CAL TB 133Full-scale seating assembly for public occupanciesThat the complete item is tested as an assembly, with this fabric and this foam
US: NFPA 260 / UFACCover fabric resistance to cigarette ignitionWhether the project accepts a fabric class in place of an assembly test
UK: BS 5852 with source 5 or crib 5Upholstered components and covers by ignition sourceWhich ignition source is required, not simply FR treated
UK: BS 7176Non-domestic seating by hazard categoryThe hazard category for that room type, stated in the schedule
EU: EN 1021-1 and EN 1021-2Ignitability by cigarette and by match flameWhether component level or finished item level is required
EU: EN 13501-1Reaction to fire classification at building levelWhether the project is asking for a product test or a building classification

Ask for the evidence in the form that survives an inspection. A supplier declaration, a material datasheet and a test report are three different documents. The useful file is an accredited laboratory report that names the tested component or assembly, the standard and edition applied, the date of test, and the fabric or foam reference actually tested. Where the tested reference differs from the specified one, the report does not cover the delivery.

Certificate per order: what to ask for, and what it cannot prove

Certificates are issued against a batch, a component and a date, not against a product name. For each delivery, agree which documents travel with the goods and which are held on file. A workable split is threefold: material and component certificates from the board, veneer, textile, foam or hardware supplier; process records from the factory, covering adhesive and finish batch data or preservative treatment; and destination documents, such as heat treatment and ISPM 15 marking for timber packing where the destination requires it.

A certificate shows that a tested sample met a stated requirement on a stated date. It does not show that this delivery used that material, that the finish reached the specified film thickness, or that the item will pass a site inspection. That is why the certificate set is read together with the approved sample, the material reference in the specification and the inspection records for the actual batch.

  • Standard, edition and test method named in the approved specification, not only in a brochure
  • Accredited laboratory report naming the component or assembly, with the date of test
  • Fabric, foam, board and finish references that match the tested reference
  • Supplier declaration for material origin, and for any treatment method claimed
  • Timber packing treated and marked to the destination requirement, with the treatment record
  • Named holder of the originals, and whether copies travel with the shipment or stay on file
  • Which certificates the project treats as a condition of payment, agreed before the order

Keep the evidence trail with the board and formaldehyde documentation, the contract upholstery performance records and the inspection gates that release each batch.

Turn your BOQ into
an approval schedule.

Submit project information ↗

Design intent · technical definition · shared decisions

What the project team should decide: Hotel Furniture Technical Specification Templates

FF&E work is the coordination of objects, materials, documents and responsibilities that make an interior usable and buildable. The page should help each party understand the next decision, not simply repeat a definition.

PerspectiveQuestion to resolveUseful output
OwnerWhat experience and operating result must be protected?Priorities, package boundaries, programme and approval authority
DesignerWhich relationships give the space its character?Selections, specifications, drawings, samples and controlled details
ProcurementWhat is being priced and compared?Common scope, quantities, inclusions, exclusions and commercial assumptions
Technical/deliveryWhat must fit, repeat, travel and be released?Interfaces, revisions, inspections, packing and closeout records

Bring to the review

Latest drawing or rendering, quantities, intended use, destination, material references, current quotation assumptions and unresolved comments.

Keep after the review

Approved revision, sample identity, decision limits, exceptions, responsible party and the evidence required before the next release.

What should the client send first?

Send the latest plans or renderings, schedule or BOQ, quantities, destination, programme and the decisions that remain open.

Does every project need the same approval process?

No. The route depends on design risk, repetition, material variation, destination requirements and what the project team must verify before release.